Review



hypix bantam 2d semiconductor x ray detector  (Rigaku Corporation)


Bioz Verified Symbol Rigaku Corporation is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94

    Structured Review

    Rigaku Corporation hypix bantam 2d semiconductor x ray detector
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    Hypix Bantam 2d Semiconductor X Ray Detector, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 94/100, based on 28 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/HyPix-Bantam/pmc13509002-61-17-9
    Average 94 stars, based on 28 article reviews
    hypix bantam 2d semiconductor x ray detector - by Bioz Stars, 2026-11
    94/100 stars

    Images

    1) Product Images from "Element-Specific Sensitivity of Lanthanoid Ions to Chiral Crystal Fields in K 3 [Ln 2 (NO 3 ) 9 ] Probed by 4f–4f Circular Dichroism"

    Article Title: Element-Specific Sensitivity of Lanthanoid Ions to Chiral Crystal Fields in K 3 [Ln 2 (NO 3 ) 9 ] Probed by 4f–4f Circular Dichroism

    Journal: Inorganic Chemistry

    doi: 10.1021/acs.inorgchem.6c02592

    X-ray crystal structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    Figure Legend Snippet: X-ray crystal structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.

    Techniques Used:

    Related Articles

    X-ray Diffraction:

    Article Title: Rational Tuning of Hygroscopic Oscillation of Stacked Nanoflake Assemblies for Continuous Ambient Energy Harvesting.
    Article Snippet: The Dynamic Mechanical nalyzer (DMA 8000, Perkin Elmer) was used to perform niaxial tension tests on SNA membranes with a loading speed f 0.1 mm/min. .. The 2D X-ray diffraction (XRD) pattern of the Xene/NP membrane was recorded using Rigaku SmartLab kW with Cu-Kα radiation (λ = 1.5418 ∀). ..

    Article Title: Modification of rheological properties and crystallization behaviors of polypropylene by addition of low-viscosity high-density polyethylene
    Article Snippet: The rheological properties and crystallization behaviors of polypropylene (PP) blends containing low-molecularweight high-density polyethylene (HDPE) were studied in a flow field under non-isothermal conditions.. The drawdown force at melt stretching (or melt tension) was enhanced by the addition of HDPE, leading to a high level of PP chain orientation, although pure HDPE showed a low drawdown force.. Moreover, the HDPE dispersion showed a shish-kebab structure with high orientation in the blends after melt stretching.

    Article Title: Interfacial chain-growth polymerization enables polypropylene-like and circular polythioglycolide
    Article Snippet: The 2D wide angle X-ray diffraction (2D-WAXD) measurement was conducted using a Rigaku NANOPIX system (Rigaku, Japan) equipped with Cu-Kα as the incident beam and Hypix-6000 as the detector. .. The 2D wide angle X-ray diffraction (2D-WAXD) measurement was conducted using a Rigaku NANOPIX system (Rigaku, Japan) equipped with Cu-Kα as the incident beam and Hypix-6000 as the detector. .. The conversion of 2D-WAXD pattern from flat plate to cylindrical manner was conducted using X-polar software developed by Precision Works NY, Inc.

    Membrane:

    Article Title: Rational Tuning of Hygroscopic Oscillation of Stacked Nanoflake Assemblies for Continuous Ambient Energy Harvesting.
    Article Snippet: The Dynamic Mechanical nalyzer (DMA 8000, Perkin Elmer) was used to perform niaxial tension tests on SNA membranes with a loading speed f 0.1 mm/min. .. The 2D X-ray diffraction (XRD) pattern of the Xene/NP membrane was recorded using Rigaku SmartLab kW with Cu-Kα radiation (λ = 1.5418 ∀). ..

    Shear:

    Article Title: Modification of rheological properties and crystallization behaviors of polypropylene by addition of low-viscosity high-density polyethylene
    Article Snippet: The rheological properties and crystallization behaviors of polypropylene (PP) blends containing low-molecularweight high-density polyethylene (HDPE) were studied in a flow field under non-isothermal conditions.. The drawdown force at melt stretching (or melt tension) was enhanced by the addition of HDPE, leading to a high level of PP chain orientation, although pure HDPE showed a low drawdown force.. Moreover, the HDPE dispersion showed a shish-kebab structure with high orientation in the blends after melt stretching.

    Structural Proteomics:

    Article Title: X-ray diffraction from a curved crystal modulated by a surface acoustic wave
    Article Snippet: Excitation and propagation of a surface acoustic wave (SAW) on a bent YZ-cut lithium niobate (LiNbO3) crystal are investigated by means of X-ray topography using synchrotron radiation.. Topographic images corresponding to the X-ray rocking curve of the crystal are obtained, with distinct intensity features arising from diffraction satellites induced by SAW propagation.. A geometric model is proposed to explain the formation of these features, which result from the interplay between crystal curvature and the angular positions of SAW-induced diffraction

    Imaging:

    Article Title: X-ray diffraction from a curved crystal modulated by a surface acoustic wave
    Article Snippet: Excitation and propagation of a surface acoustic wave (SAW) on a bent YZ-cut lithium niobate (LiNbO3) crystal are investigated by means of X-ray topography using synchrotron radiation.. Topographic images corresponding to the X-ray rocking curve of the crystal are obtained, with distinct intensity features arising from diffraction satellites induced by SAW propagation.. A geometric model is proposed to explain the formation of these features, which result from the interplay between crystal curvature and the angular positions of SAW-induced diffraction

    Small Angle X-ray Scattering:

    Article Title: Structural organization of TAM receptor ectodomains
    Article Snippet: .. Small-angle X-ray scattering (SAXS) SAXS data collected at Yale were recorded at 4 °C on Rigaku BioSAXS-2000nano 2D Kratky block camera system with a Rigaku 007HF rotating anode source and a Rigaku HyPiX-3000 HPAD CCD detector, with 90-min exposures and frames recorded every 10 min. Data were collected using SAXLab version 4.0.2 (Rigaku). ..

    Blocking Assay:

    Article Title: Structural organization of TAM receptor ectodomains
    Article Snippet: .. Small-angle X-ray scattering (SAXS) SAXS data collected at Yale were recorded at 4 °C on Rigaku BioSAXS-2000nano 2D Kratky block camera system with a Rigaku 007HF rotating anode source and a Rigaku HyPiX-3000 HPAD CCD detector, with 90-min exposures and frames recorded every 10 min. Data were collected using SAXLab version 4.0.2 (Rigaku). ..



    Similar Products

    99
    Xenocs Inc 2d small angle x ray
    2d Small Angle X Ray, supplied by Xenocs Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/Xeuss+Pro/10__1038_slash_s41467___026___77562___5-279-6-14
    Average 99 stars, based on 1 article reviews
    2d small angle x ray - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    94
    Rigaku Corporation hypix bantam 2d semiconductor x ray detector
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    Hypix Bantam 2d Semiconductor X Ray Detector, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/HyPix-Bantam/pmc13509002-61-17-9
    Average 94 stars, based on 1 article reviews
    hypix bantam 2d semiconductor x ray detector - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    99
    Rigaku Corporation x ray diffractometer 2d waxd
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    X Ray Diffractometer 2d Waxd, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/SmartLab/10__1016_slash_j__polymer__2026__130648-90-8-12
    Average 99 stars, based on 1 article reviews
    x ray diffractometer 2d waxd - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Bruker Corporation x ray diffraction 2d xrd patterns
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    X Ray Diffraction 2d Xrd Patterns, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/APEX/pmc13396452-204-1-12
    Average 99 stars, based on 1 article reviews
    x ray diffraction 2d xrd patterns - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Rigaku Corporation 2d x ray diffraction xrd pattern
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    2d X Ray Diffraction Xrd Pattern, supplied by Rigaku Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/SmartLab/pm42080241-154-1-13
    Average 99 stars, based on 1 article reviews
    2d x ray diffraction xrd pattern - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    98
    Dectris AG 2d eiger2 x 4m detector dectris baden daettwil switzerland
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    2d Eiger2 X 4m Detector Dectris Baden Daettwil Switzerland, supplied by Dectris AG, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/eiger2/pm42031808-214-2-7
    Average 98 stars, based on 1 article reviews
    2d eiger2 x 4m detector dectris baden daettwil switzerland - by Bioz Stars, 2026-11
    98/100 stars
      Buy from Supplier

    98
    Dectris AG 2d eiger2r 4m x ray detector
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    2d Eiger2r 4m X Ray Detector, supplied by Dectris AG, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/eiger2/10__1038_slash_s41545___026___00577___4-272-9-8
    Average 98 stars, based on 1 article reviews
    2d eiger2r 4m x ray detector - by Bioz Stars, 2026-11
    98/100 stars
      Buy from Supplier

    98
    Dectris AG 2d x ray detector
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    2d X Ray Detector, supplied by Dectris AG, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/eiger2/10__1002_slash_adpr__202500325-584-16-22
    Average 98 stars, based on 1 article reviews
    2d x ray detector - by Bioz Stars, 2026-11
    98/100 stars
      Buy from Supplier

    95
    Gold Biotechnology Inc x problock gold 2d protease inhibitor cocktail
    <t>X-ray</t> <t>crystal</t> structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.
    X Problock Gold 2d Protease Inhibitor Cocktail, supplied by Gold Biotechnology Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/2d+x/ProBlock+Gold+2D/bio_rxiv__64898__2026__02__23__707533-58-27-36
    Average 95 stars, based on 1 article reviews
    x problock gold 2d protease inhibitor cocktail - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    Image Search Results


    X-ray crystal structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.

    Journal: Inorganic Chemistry

    Article Title: Element-Specific Sensitivity of Lanthanoid Ions to Chiral Crystal Fields in K 3 [Ln 2 (NO 3 ) 9 ] Probed by 4f–4f Circular Dichroism

    doi: 10.1021/acs.inorgchem.6c02592

    Figure Lengend Snippet: X-ray crystal structures of l -K 3 [Ln 2 (NO 3 ) 9 ] and d - K 3 [Ln 2 (NO 3 ) 9 ] ( P 4 1 32 and P 4 3 32) determined by SCXRD measurements: Ln = (a) La, (b) Ce, (c) Pr, (d) Nd, (e) Sm, (f) Eu, and (g) Gd.

    Article Snippet: SCXRD data were collected at 293 K using a Rigaku XtaLAB mini II diffractometer equipped with a HyPix-Bantam 2D semiconductor X-ray detector.

    Techniques: